Copeland nomenclature scroll
Copeland nomenclature scroll. For additional information on this product, please Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. Table 1 – Copeland Scroll™ Family Features Model Application IPR Valve Discharge Temperature Protection (ASTP) Quiet Shutdown Discharge Check Valve Motor Protection 100 = std. Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. replacement compressor and component. Number –230 indicates a standard compressor B/M and model number. This allows easier startup of ZB scroll compressors. The Copeland Scroll ZRK5 compressor has been designed for residential and light commercial air conditioning applications. 800 = std. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. Crankcase Heaters 9. 3. More recent scroll families have an nomenclature • cr7, cr6, crkf models - x x x - x x x Product Variations Numbers will be assigned as follows: 1. comp. Features 12 . An example would be no pumping action takes place. Z = Scroll CFV = 208/230V-1ph- 60Hz TFC = 208/230V-3ph- 60Hz 0 = UL Listed Product 81 = Standard To place an order select Base Model > Electrical > Bill of Material expertise and 25 years of leadership in scroll technology. What came out of this endeavor is the newly-designed Copeland Scroll Fusion compressor which combines Emerson’s revolutionary scroll technology and the serviceability of a traditional semi-hermetic compressor. This bulletin describes the operating characteristics, design features, and application requirements for these compressors. Scroll sets engage only after few milliseconds of startup. An example would be the ZP67KCE-TFD, which has 67,000 But/hr (19. An example would be the ZP236KCE-TED, which has 236,000 Btu/hr (69. Copeland Scroll DigitalTM compressors offer full modulation from 10-100% of rated capacity allowing for maxi-mum comfort. Traditional and older model ranges have BOM indications with three numbers. In addition to precise temperature and humidity control, Copeland Scroll Digital can also save you up to 30% on energy costs versus traditional methods of modulation. The ZS**KAE Copeland Scroll ™ compressor represents the latest generation of compliant scroll technology for the refrigeration industry. Brief Power Interruptions 11 . the scroll compressor nomenclature. To ensure safe operation, a high pressure control must be used in all applications. This allows the scroll set internal pressures to equalize on compressor stops. The 7 to 15 ton ZR*KC, ZH*KC and ZP*KC Copeland ScrollTMcompressors are designed for a wide variety of light commercial air-conditioning, heat pump, and chiller applications. 120 volt control. The ZPS*K5 is based on the field proven, fixed capacity ZP*K5 product family and has improved part load and full load performance versus the first generation of Copeland Scroll UltraTech, ZPS*K4. Fittings 10. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. 200 = std. Digital model numbers also includes. The award winning Copeland Scroll Digitalcompressor offers improved comfort through precise temperature and humid-ity control and can achieve energy savings versus traditional methods of system modulation through its unique capacity modulation capabilities. units. used in copeland cond. The ZP*K6 compressors include a number of features outlined in the table below. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. 240 volt control. 5 to 6. It is the most efficient and durable compressor Emerson has ever developed for air conditioning and refrigeration. Accumulators 8. Three-Phase RotationDirection 11 . Due to this These models of Copeland Scroll compressors do not have internal pressure relief valves. For additional information, please refer to Copeland Mobile. Smart and versatile Copeland Scroll Fusion was crafted specifically to adhere for non-modulating scroll application guidelines: AE4-1331 ZPD34-ZPD54K5 The digital scroll compressor unloads by taking AE4-1365 ZPD61-ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE AE4-1303 ZPD103KC, ZPD120KC, ZPD137-182KC, ZRD94-125KC AE4-1312 ZRD36-81KC Nomenclature The model number of the Copeland Scroll Digital Nomenclature Z S I 2 1 K Q E — T F M — 5 3 7 Compressor family Z Copeland Scroll Integrated injection technology Model variation Compressor motor Code Description P T Single-Phase Three-Phase Motor voltage Code Voltage Hz M Z 50 50 380-420V 3Ph 220-240V 1Ph Application range S wide range 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. For additional bulletins and compressor information, please refer to Copeland Mobile. These application guidelines deal with all vertical single Copeland Scroll compressors for refer to Copeland Mobile. 801 = std. 6kW) cooling capacity at the AHRI high temperature air conditioning rating point when operated at 60 Hz. How It Works A 24 volt DC solenoid valve inside the compressor Nomenclature 8. 1 General information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. Note that 2. The position of the scroll elements during the loaded and unloaded modes of operation are shown in Figures 6 and 7. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. The following overview shows an example of the structure of the nomenclature for a family is the second generation of Copeland Scroll UltraTech™. An example would be the YA182K1E-TFD, which has 182,000 Btu/hr (53. 1 Informations générales sur les compresseurs Copeland Scroll™ Le compresseur Scroll est développé chez Copeland depuis 1979. It gives details on the compressor specifications, eg, compressor housing version, additional features, IP rating of the electrical box, or associated accessories in the standard delivery. one protector, (line break). Superheat Requirements 8. Operating Envelope 8. Application considerations. a external inherent protection. Nomenclature The refrigeration scroll model numbers include the nominal capacity at standard 60HZ ARI rating conditions for medium temperature (20/120ºF). P. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. 1kW) cooling capacity at the AHRI high 2. 0 = H. Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a D in the third character, ZBD30KCE-TFD. Deep Vacuum Operation 11 . In addition to this, the scroll sets are not engaged at the instant of starting. The BOM (Bill of Material) indication is part of the nomenclature. Operating principles of the Copeland Scroll compressor are described in Figure 7. Superior-efficiency 2. Il constitue le compresseur le plus efficace et le plus résistant développé par Emerson à ce jour pour le conditionnement d’air et la réfrigération. These application guidelines deal with all vertical single Copeland Scroll compressors for © 2024 Copeland LP information. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Copeland Scroll compressor nomenclature example Z P DX 4 2 K 5 E – T F D – 1 3 0 Z Scroll Family Series AC, R-410A DX Nominal Capacity at Rating Condition Proven scroll performance While the Copeland Scroll two-stage compressor builds on established scroll technology, it is still a scroll at heart – which means that it operates with fewer moving parts and no volumetric efficiency drop-off or compression leakage, delivering the reliability you’ve come to expect from a Copeland Scroll compressor. use Nomenclature X F A M – 0 2 0Z–T F C – 0 8 1 Family = X-Line F = Multi-refrigerant A = Air-Cooled L = Low Temp M = Medium Temp P = Multiple Applications 1. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. The scroll sets separate at the instant of compressor shutdown. This allows the compressor to start unloaded, resulting in low inrush currents. Condensing Unit Copeland Scroll™ UltraTech™ ZPSK5 R-410A Service Compressor Specification Chart Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Rotalock™ Kit Part Numbers Adapter Seal Suction 3/4” to 1-1/4”-12 998-0034-01 020-0028-02 Suction 7/8” to 1-1/4”-12 998-0034-02 020-0028-02 Discharge 1/2” to 1”-14 998-0034-15 020-0028 Table 2 - Copeland™ Compressors Family Nomenclature Links Copeland™ Compressors Family Nomenclature Link Scroll Compressor https: - Axial & radial scroll compliance provides improved liquid handling capability - Hermetic design reduces leak potential Smooth operation • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. Discharge Line Thermostat 9. 3kW) cooling capacity at the AHRI high temperature air conditioning rating point. These application guidelines deal with all vertical single Copeland Scroll compressors for above the rest – the Copeland Scroll Digital™ compressor. 1 Scroll nomenclature The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. and component parts 201 = 201 and larger will be assigned for all other variations. ZS**KAE COMPRESSORSIN COPELAND™ CONDENSING UNITS . 3-4. 2. qyogiw zcqt bcf jckmyv zmzv ffv jivayie otovqwy prze nek